Skip to content
Al-Zouk Al-Massi workshop markAl-Zouk Al-Massi

CR 2055139268VAT 311901806100003Dammam · Jubail · Kingdom-wide

· Jubail

When to rewind an industrial motor in Jubail

Rewind a motor when the winding is burned, earthed, or the insulation class has collapsed — not when the only fault is bearings. Al-Zouk Al-Massi records turns and wire size in Jubail before old copper comes out, then tests the rewind. Dammam and other Saudi sites send the nameplate photo with the machine.

Disassembled three-phase motor with copper stator windings and squirrel-cage rotor
Copper stator · rotor · Wikimedia / Zureks

What a rewind actually is

A rewind replaces failed coils to the original turns, connection, and insulation class. Torque and temperature stay where the OEM designed them only if that data is copied first. A generic kit turns a 110 kW pump motor into a different machine.

Faults that mean rewind, not a bearing job

Earth on the winding, burned slots after single-phasing, and insulation resistance that will not recover after a dry-out are rewind jobs. Noise and heat with a healthy winding are often bearings or alignment — those stay mechanical.

What to send from Dammam or site

Nameplate photo, kW, voltage, speed, and the symptom (trip, earth, smoke). The shop is in Oraifi Industrial District, Jubail. Collection both ways is arranged. Call 056 489 5748.

Related trade09 Motors rewinding

Industrial electric motor mounted on plant machinery

Contact

Send a query with the nameplate and the fault.

The form is used only to reply to this query. It is not a mailing list.

Call 056 489 5748Contact us

056 489 5748